Register Here | Login | My Account | Shopping Cart | Customer Service | Search| Items in Cart (0) | Quotes (0)
Call 1-800-369-6671
(Military/Intl Sales - 214-616-6180)
LIGHT TOWERS IN STOCK
       
 

Vast Inventory for Fast Shipping. Custom Builds Available, Rentals and Sales.
Most items in stock for fast shipping!! UPS Ship Map Credit cards & Paypal Accepted
Intrinsically Safe Lights - Explosion Proof Electric Inline Axial Fan - Class I, Div. I - 15' Conductive Duct - 1/3 HP Engine You're NOT logged in, Please log in   

Search:
Company Information

Product #:

         
Aevum Control Lighting and Equipment - IIoT
Explosion Proof Lights
Industrial and Vaporproof Emergency Failsafe Lighting
Industrial Cord Reels and Tool Taps
Machine Vision Lights
Megatower™
QC Series Industrial Portable Lighting - Quick Change Mount
Rig Lights
Stadium lights
String Lights and Temporary Light Stringers
Tank Cleaning Lights
Three Phase Motor Soft Starters
Vapor Proof LED Lights
Variable Frequency Drives (VFDs)
Vehicle Mounting Plates
Workboat Light Fixtures & Lighting Equipment
Color Changing LED RGB Lighting
Explosion Proof Cord Reels
GOLIGHT Spotlights
Larson FUTURE - Lease Lighting
Remote Area Lighting and Scene Lights
Utility Bucket Mount, Receiver Hitch & Trailer Mount Lighting
Butane and Solvent Extraction Room Lighting and Equipment
DC to DC Transformers and Power Supplies
Explosion Proof Fans & Blowers
Explosion Proof Paint Spray Booth Approved Lights
Explosion Proof String Lights
Explosion Proof Switchgear & Controls
Fleet Service Lights and Lighting Equipment
Industrial Equipment Trailers
Industrial Handlamps & Droplights
ISO 14644/FS-209E Clean Room Lighting
LED Blasting Lights
Night Time Fishing Lights
Portable AC Power Supply Units
Portable Power Distribution Panels
Power Distribution Panels with KVA Transformers
Self-Contained Lighting
Service Pit Lighting
Solar Generators & Solar Powered Lighting
Agricultural Farm Equipment Lighting & Beacons
Explosion Proof Cameras & Surveillance Systems
Explosion Proof Emergency Lights
Explosion Proof Heaters
Garage & Gas Station Canopy Lights
LED Grow Lights
LED Lights
NDT Ultraviolet Lights
Portable Hazardous Location Lighting
Radio Communication Towers and Equipment
Salt Water Processing Equipment
Shelter & Tent Lighting
Thermal Monitoring Cameras and Systems
48V LED Equipment Lights
ATEX Rated Explosion Proof Lights
Automotive Lighting
Class Rated Signals, Alarms, and Systems
Hazardous Location Area Lights and Portable Lighting
HID Equipment Lights
Hot Work Permit Lighting and Equipment
Hunting Lights
Industrial lasers
Industrial Transformers
Light Towers
NEW CATEGORY
Outdoor Lighting
Remote Security and Surveillance Systems
Temporary Construction Lights
Vehicle Mounted Spotlights
Equipment & Heavy Machinery LED Light Package Fitouts
Phase Converters - Single to Three Phase
Marine Shore Power Cords and Equipment
24 Volt Military Lights
Disaster Relief / First Responders / Search & Rescue Lighting
Plastic Handcuff Key
110/120 Volt Flood Lights
Post Mount Spotlights
Magnetic Work Lights
Crank-up Light Masts
**********    
Intrinsically Safe Lights
Military Flashlights
LED Waterproof Lanterns
Work Area Lights
12 Volt Flood Lights
**********    
**********    
Boat Spotlights
New Boat Lights
HID Boat Lights
Boat Dock Lights
**********    
Remote Control Lights
Control Lights
Tow Lights
Magnetic Control Lights
**********    
NEW Lights and New Products
Evaporative Coolers
Police Equipment
AC/DC Transformers
Power Supplies
**********    
Military Spotlights 24V
Infrared Filters, Covert Covers, and Blackout IR Lenses
Military Equipment
Ultralife Batteries
Remote Control Pan Tilt Base
**********    
Larson Electronics Spotlights
Larson Electronics Parts
Replacement Lamps
Cords - Brackets
Portable Wheeled Generators
Non-Hazardous Location Extension Cords / Plugs / Outlets
**********    
HID Work Lights
HID Dive Lights
HID Off Road Lights
Acro Lights HID Lights
Halogen Lights
**********    
Acro Light Flashlight
Xenon HID Flashlights
Powerlight Flashlight
HID Flashlights
Xenon Flashlights
**********    
LED Status Lights
Forklift Lights
Tractor Lights
HID Post Mount Lights
Roof Mount Lights
Post Mount Light parts
**********    
Flashlight Holder
Magnet Spotlight Base
Tripods-Magnetic Base
**********    
Recharging Spotlights
Fire Rescue Lights
LED Street Lights
Utility Lights
**********    
Hazard Lights
Strobe Lights - Battery Operated
Strobes & Beacons
Strobe Light Bars
**********    
Headlights - Headlamps - Hard Hat Lights
Flashlights
**********    
Suction Mount Lights
Magnetic Spotlights
12/24 Volt Spotlights
Gifts For Men
**********    
**********    
New 12 / 24 Volt Lights
Explosion Proof Accessories and Replacement Parts
Explosion Proof Lighting
Explosion Proof Hand Lamps (Drop Lights)
Explosion Proof Lights - Stand/Dolly
Explosion Proof Tank Lights
Explosion Proof Phones and Intercoms
Explosion Proof Extension Cords
Black Friday & Cyber Monday Specials
Crane Lights
Explosion Proof Light Rentals
General Light Rentals
Light Tower and Light Plant Rentals
Power Distribution Rentals
**********    
Power Plant Lighting
Refinery lights
Environmental Services Lights
Aerospace Lights
Chemical Plant Lights
Food Grade Safe Lights
Film and Entertainment Lights
Handheld Meters and Devices
Waste Water Treatment Lights
Mining Lights
Ship Yard Lights
Work Site Lighting
         

Explosion Proof Electric Inline Axial Fan - Class I, Div. I - 15' Conductive Duct - 1/3 HP Engine




Part # EPF-10P.3    Price: $2,263.65

Spec Sheet   Hoja de Especificaciones   

Dimensions   Manual   Spectrum Chart   
STEP   

Video 1   Video 2   Video 3   Video 4  

Made in the USA

The Larson Electronics EPF-10P.3 Explosion Proof Electric Inline Axial Fan with 21 foot static conductive duct is UL and CUL listed and safely and effectively redirects stale air from hazardous location areas. This fan includes a 15 foot static conductive duct and a shorter 6 foot conductive duct, is designed for portability, and can be linked in series when larger lengths of conductive duct are needed.

This explosion proof fan delivers high-performance airflow with a 1,390 overall CFM rating and 973 CFM when fitted with a 25ft. duct and a 90 degree bend. The 1/3 horsepower electric motor runs from standard 115 VAC and pulls 12.6 amps. Added safety features include a prewired explosion proof switch, dual grounding lugs on the steel housing, and 10 feet of cord fitted with a 5-15 straight blade explosion proof plug. Meets UL and Canadian UL safety ratings for Class 1, Division 1, Groups C and D & Class II Division 1, Groups E, F and G.

Click Photo to Enlarge
Click Photo to Enlarge
Click Photo to Enlarge

This explosion proof fan is designed for portability and durability with a light weight compact body constructed of powder coated steel and a non-sparking aluminum blower wheel. Rubber coated base feet and an integral carry handle provide easy transport and secure placement when set down on a flat surface. This unit is available with either an 8 inch or 10 inch intake and exhaust flange, and includes a built in automatic reset thermal overload for added protection.

Note on Explosion Proof Fans: Can be used as an intake and an exhaust fan.

Exhaust Configuration
Intake Configuration

INCLUDES:
1. Hazardous location ventilation fan (blower)
2. 15 feet static conductive duct
3. 6 feet static conductive duct
4. Dust carrier (holds up to 50ft. of duct)
5. Universal mount
6. Static conductive 90 degree elbow for saddle vent
7. Static conductive saddle vent







Features:
• 1/3 HP electric motor, 115 VAC, 12.6 amp
• Explosion-proof switch installed and wired
• 8 or 10 inch intake and exhaust flange
• 1390 cfm free air delivery
• 973 cfm when a 25ft. duct and a 90 degree bend are present while in use.
• 72 dbA @ 3ft.
• Approved for Class I, Div. 1, Groups C and D and Class II, Div. 1, Groups E, F, G
• Aluminum non-sparking blower wheel
• Dual grounding lugs installed on steel housing
• All Steel, powder coated red with rubber base feet
• Automatic reset thermal overload
• Carry handle frame
• Pre-Wired With 10 Ft. Cord
• Pre-wired with a 15 amp explosion proof 5-15 style plug

The ducts on this fan consist of single-ply polyester reinforced PVC vinyl fabric hose with an external wear strip reinforced with a spring steel wire helix. The ducting is lightweight for these blower applications and is highly compressible. The retractability of the static conductive duct allows for convenient storage and easy transport in a fraction of its fully extended length and has low friction loss. The wearstrip offers external abrasion resistance, and is listed as YL 94 V-0 flame retardant. Ambient temperature for the fan ranges from -20 degrees to 180 degrees Fahrenheit.


Specifications / Additional Information

EPF-10P.3Explosion Proof Inline Axial Fan UL and C-UL Listed
Air consumption: 38 cfm Class I, Div. 1 & 2, Groups C and D
Voltage: 115 VAC Class II, Div. 1 & 2, Groups E, F, G
Amps : 86 Dba12.6 T3C Temp rating -30C to 160C
Motor: 1/3 Horsepower Meets UL and Canadian UL Safety Ratings
CFM Delivery : 1390
Noise Level: 72 dbA @ 3ft
Fan Type: Inline Axial Fan

Size: 16”W x 16.75”H x 12.5”D Special Orders- Requirements
Wiring: 10 Foot Cord w 5-15 Exp Proof  Plug Contact us for special requirements
Protection: Dual Lug Ground Body/Automatic Reset Thermal Overload Toll Free: 1-800-369-6671
Intl: 1-903-498-3364
E-mail: sales@larsonelectronics.com

Scroll Down to Purchase-


Click here to view the Explosion Proof Light Design Description

Part #:EPF-10P.3 (48377)
In Stock:Yes

















































Customer Rating:
9.4 / 10
21148 customer reviews




    Sale Prices in RED
Product  Part #PriceOption 1Option 2Option 3Qty
Explosion Proof Electric Inline Axial Fan - Class I, Div. I - 15' Conductive Duct - 1/3 HP Engine EPF-10P.3$2,263.65N/AN/AN/A 




 




Static Conductive Duct - EPF-8P and EPF-10P Explosion Proof Blowers - 8 inch OD - 25 foot long -

$290.00


Explosion Proof Ventilation Duct Coupling

$60.00
  

Related Articles

08/15/12Hazardous Location Classification: Basic Class and Divisions Rundown

Class 1 Division 2 locations are areas where flammable gases, liquids or vapors may be present under abnormal conditions such as during a container failure or accidental opening of a closed system. In these locations, gases and vapors are not normally present except within closed systems or in storage, but can become a hazard when they escape confinement and contaminate the ambient atmosphere. [...]

09/21/11IECex/ATEX and North American NEC HAZLOC Equipment Classification

North America is presently not operating with the IECex/ATEX schemes although some effort has been made to produce some homogenity between North American and European Standards, most notably the US and Canada's adoption of a Zone system (NEC 505) modeled after European Schemes. However, despite the great similarity between North American and European Zone systems, they are not identical and are not interchangeable. [...]

07/13/11Combustible Dust Standards and Preemptive Safety

As of this writing, OSHA has yet to institute a solid set of standards for combustible dusts. Many officials adopt NFPA recommendations into their local fire codes as a result in order to attempt some level of regulatory standards across a broad spectrum. Whether or not any meaningful regulation emerges from OSHA in the near future, it is best that any industry or commercial operation associated with combustible dusts be preemptive and adhere to any local regulations as well as adopt their own m [...]

12/16/10How Do You Know If a Light is really Explosion Proof?

Hazardous location lighting equipment is in the simplest explanation used in places where concentrations of volatile gases, flammable dust or particulates, or flammable chemicals are high enough to present a danger of ignition that can lead to explosion or fire. [...]

08/02/10Confined Space Lighting for Hazardous Locations

Confined spaces represent some of the most dangerous work places in commercial industries. Because of their enclosed nature confined spaces are poorly ventilated and allow volatile gases, fumes, vapors, and particulates to accumulate and increase in atmospheric density to potentially explosive levels. Confined spaces represent a hazardous work area and are loosely defined by a few general characteristics. [...]
Home | Contact Us | Return Policy | Privacy Policy | Security Policy | Copyright © 2006-2016. All Rights Reserved.