The MT-PDO-3P-12470GRDY-1500KVA-480Y.277-N3R 12470GRDY 3 Phase Energy Efficient Pad Mount Loop Feed Dead Front Transformer from Larson Electronics is powerful, reliable and designed with the environment in mind. Suitable for both indoor and outdoor applications, the MT-PDO-3P-12470GRDY-1500KVA-480Y.277-N3R provides increased reliablity and protection against critical equipment failures. The lower operating costs, lower heat emissions and lower cost of ownership make this transformer ideal for a wide range of applications and businesses.
*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*
Transformer Features: With a transformer rating of 1500kVA, the MT-PDO-3P-12470GRDY-1500KVA-480Y.277-N3R transformer is a three phase unit with a primary voltage of 12470GRDY/7200 Grounded Wye. It also provides a secondary voltage of 480Y/277 Wye. Featuring robust construction, this unit`s cores are manufactured with non-aging, cold-rolled silicon steel laminations using state of the art technology. The MT-PDO-3P-12470GRDY-1500KVA-480Y.277-N3R is a grounded wye connection transformer and therefore must be connected phase-to-ground on a grounded wye system.
This unit boasts a low cost of ownership and is highly energy efficient. Lower heat emissions mean less cooling is needed as well. The Standard NEMA Type 3R enclosure makes the unit suitable for both indoor and outdoor applications and it can be floor mounted. The unit also features mineral oil cooling and a 65°C temperature rise and is rated IP24. The MT-PDO-3P-12470GRDY-1500KVA-480Y.277-N3R is designed so that no excess oil heating occurs from unbalanced loads or phase loss on the primary side.
Benefits: The MT-PDO-3P-12470GRDY-1500KVA-480Y.277-N3R pad mount loop feed transformer offers many benefits to the consumer. Precision cut copper transformer winding material help to improve performance. The close tolerances used during manufacturing also eliminates burrs which hinder performance. Each core is specially coated to prevent the ingress of moisture and are electrically balanced to minimize axial forces during short circuit situations.
This transformer provides owners with significant energy savings as well as offering environmental benefits. Higher efficiency not only extends the life of the transformer, but also turn into cost savings for owners in the form of lower energy bills and decreased cost of ownership. Integrated floor and wall mounting brackets make installation fast and easy and the offset outward facing floor installation holes allow for easy power tool access.
Applications: General purposes.
Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1-800-369-6671 or sales@larsonelectronics.com to discuss your specific requirements.
Specifications / Additional Information
MT-PDO-3P-12470GRDY-1500KVA-480Y.277-N3R Pad Mount Transformer |
Ratings |
Phase: Three Phase |
Listed for United States and Canada |
Frequency: 60Hz |
ONAN Cooling |
kVA: 1500 |
IP24 Rated |
Primary Voltage: 12470GRDY/7200 Grounded Wye |
Mineral Oil Filled |
Primary kV Class: 15kV |
Dead Front |
Primary Connection: Grounded Wye |
Loop Feed |
Primary BIL: 95kV |
|
Primary FCAN: 2 x 2.5% |
|
Primary FCBN: 2 x 2.5% |
|
Tap Changer: 100 Amp 5-Position Tap Changer |
|
High Voltage Bushings: (6) 200A Copper Bushing Wells & Removeable Studs |
|
Neutral Bushing: 5/8" Copper Stud w/ 4-Hole Screw On Spade Bushing |
|
Load-Breaking Switch: None |
|
Arresters: None |
|
Overcurrent Protection: None |
|
Secondary Voltage: 480Y/277 Wye |
|
Secondary Connection: Wye |
|
Secondary BIL: 30kV |
|
Low Voltage kV Class: 1.2kV |
|
Low Voltage Bushings: (4) Integral Aluminum 12-Hole Spade Bushings |
|
Bushing Supports: Standard LV Bushing Support Assembly |
|
IEEE K-Dimension: Loop Feed per IEEE C57.12.34-2015 Figure 11 Minimum Dimensions (Without Bails)
|
|
Notifications: Danger High Voltage Decal |
|
Notifications: Mr. Ouch Decal Assembly - English/Spanish |
|
Notifications: Non-PCB Decal |
|
Gauges & Fittings: Liquid Level Gauge |
|
Gauges & Fittings: Thermometer - Dial Type |
|
Gauges & Fittings: Pressure/Vacuum Gauge |
|
Gauges & Fittings: 1" Drain Valve w/ Sample in LV Compartment |
|
Gauges & Fittings: Pressure Relief Device, 35 SCFM |
|
Tank Accessories: (3) IEEE Standard Two-Hole Ground Pads |
|
Winding Material: Copper |
|
Efficiency: DOE 2016 |
|
Cooling Class: ONAN |
|
Insulating Fluid: Mineral Oil |
|
Fluid Volume: 295 Gallons |
|
Fluid Weight: 2199 lbs |
|
Elevation: Designed for Operation at 1000M (3300`) Above Sea Level |
|
Temperature Rise: 65°C |
|
Impedance (Std): 5.73% |
|
Sound Level: NEMA TR1 Standard |
|
Cabinet: 24" Deep Cabinet |
|
Cabinet Hardware: Penta-Head Cabinet Door Bolts |
Special Orders- Requirements |
Finish: Munsell Green (Munsell 7GY 3.29/1.5) Topcoat |
Contact us for special requirements |
Dimensions: - |
Toll Free: 1-800-369-6671 |
Weight: 9018 lbs |
Intl: 1-903-498-3363 |
Mounting: Pad Mount |
E-mail: sales@larsonelectronics.com |
| -Scroll Down to Purchase-
|