Register Here | Login | My Account | Shopping Cart | Customer Service | Search| Items in Cart (0) | Quotes (0)
Call 1-800-369-6671
(Military/Intl Sales - 214-616-6180)
LIGHT TOWERS IN STOCK
       
 

Vast Inventory for Fast Shipping. Custom Builds Available, Rentals and Sales.
Most items in stock for fast shipping!! UPS Ship Map Credit cards & Paypal Accepted
Home - Articles You're NOT logged in, Please log in   

Search:
Company Information

Product #:

         
ATEX and IEC Ex Flame-proof Explosion Proof Lighting & Equipment
Explosion Proof Lights
Explosion Proof Motors - Motors for Hazardous Locations
Industrial and Vaporproof Emergency Failsafe Lighting
Industrial Cord Reels and Tool Taps
Industrial Work Area Heaters
Machine Vision Lights
Megatower™
QC Series Industrial Portable Lighting - Quick Change Mount
Rig Lights
Stadium lights
String Lights and Temporary Light Stringers
Tank Cleaning Lights
Three Phase Motor Soft Starters
Vapor Proof LED Lights
Variable Frequency Drives (VFDs)
Vehicle Mounting Plates
Workboat Light Fixtures & Lighting Equipment
Yacht Engine Room Lights
Color Changing LED RGB Lighting
Explosion Proof Cord Reels
GOLIGHT Spotlights
Larson FUTURE - Lease Lighting
Remote Area Lighting and Scene Lights
Utility Bucket Mount, Receiver Hitch & Trailer Mount Lighting
Aevum Control Lighting and Equipment - IIoT
Butane and Solvent Extraction Room Lighting and Equipment
DC to DC Transformers and Power Supplies
Explosion Proof Fans & Blowers
Explosion Proof Paint Spray Booth Approved Lights
Explosion Proof String Lights
Explosion Proof Switchgear & Controls
Fleet Service Lights and Lighting Equipment
Industrial Equipment Trailers
Industrial Handlamps & Droplights
ISO 14644/FS-209E Clean Room Lighting
LED Blasting Lights
Night Time Fishing Lights
Portable AC Power Supply Units
Portable Power Distribution Panels
Power Distribution Panels with KVA Transformers
Self-Contained Lighting
Service Pit Lighting
Solar Generators & Solar Powered Lighting
Agricultural Farm Equipment Lighting & Beacons
Explosion Proof Cameras & Surveillance Systems
Explosion Proof Emergency Lights
Explosion Proof Heaters
Garage & Gas Station Canopy Lights
LED Grow Lights
LED Lights
NDT Ultraviolet Lights
Portable Hazardous Location Lighting
Radio Communication Towers and Equipment
Salt Water Processing Equipment
Shelter & Tent Lighting
Thermal Monitoring Cameras and Systems
48V LED Equipment Lights
ATEX Rated Explosion Proof Lights
Automotive Lighting
Class Rated Signals, Alarms, and Systems
Hazardous Location Area Lights and Portable Lighting
HID Equipment Lights
Hot Work Permit Lighting and Equipment
Hunting Lights
Industrial lasers
Industrial Transformers
Light Towers
Outdoor Lighting
Remote Security and Surveillance Systems
Temporary Construction Lights
Vehicle Mounted Spotlights
Equipment & Heavy Machinery LED Light Package Fitouts
Phase Converters - Single to Three Phase
Marine Shore Power Cords and Equipment
24 Volt Military Lights
Disaster Relief / First Responders / Search & Rescue Lighting
Plastic Handcuff Key
110/120 Volt Flood Lights
Post Mount Spotlights
Magnetic Work Lights
Crank-up Light Masts
**********    
Intrinsically Safe Lights
Military Flashlights
LED Waterproof Lanterns
Work Area Lights
12 Volt Flood Lights
**********    
**********    
Boat Spotlights
New Boat Lights
HID Boat Lights
Boat Dock Lights
**********    
Remote Control Lights
Control Lights
Tow Lights
Magnetic Control Lights
**********    
NEW Lights and New Products
Evaporative Coolers
Police Equipment
AC/DC Transformers
Power Supplies
**********    
Military Spotlights 24V
Infrared Filters, Covert Covers, and Blackout IR Lenses
Military Equipment
Ultralife Batteries
Remote Control Pan Tilt Base
**********    
Larson Electronics Spotlights
Larson Electronics Parts
Replacement Lamps
Cords - Brackets
Portable Wheeled Generators
Non-Hazardous Location Extension Cords / Plugs / Outlets
**********    
HID Work Lights
HID Dive Lights
HID Off Road Lights
Acro Lights HID Lights
Halogen Lights
**********    
Acro Light Flashlight
Xenon HID Flashlights
Powerlight Flashlight
HID Flashlights
Xenon Flashlights
**********    
LED Status Lights
Forklift Lights
Tractor Lights
HID Post Mount Lights
Roof Mount Lights
Post Mount Light parts
**********    
Flashlight Holder
Magnet Spotlight Base
Tripods-Magnetic Base
**********    
Recharging Spotlights
Fire Rescue Lights
LED Street Lights
Utility Lights
**********    
Hazard Lights
Strobe Lights - Battery Operated
Strobes & Beacons
Strobe Light Bars
**********    
Headlights - Headlamps - Hard Hat Lights
Flashlights
**********    
Suction Mount Lights
Magnetic Spotlights
12/24 Volt Spotlights
Gifts For Men
**********    
**********    
New 12 / 24 Volt Lights
Explosion Proof Accessories and Replacement Parts
Explosion Proof Lighting
Explosion Proof Hand Lamps (Drop Lights)
Explosion Proof Lights - Stand/Dolly
Explosion Proof Tank Lights
Explosion Proof Phones and Intercoms
Explosion Proof Extension Cords
Black Friday & Cyber Monday Specials
Crane Lights
Explosion Proof Light Rentals
General Light Rentals
Light Tower and Light Plant Rentals
Power Distribution Rentals
**********    
Power Plant Lighting
Refinery lights
Environmental Services Lights
Aerospace Lights
Chemical Plant Lights
Food Grade Safe Lights
Film and Entertainment Lights
Handheld Meters and Devices
Waste Water Treatment Lights
Mining Lights
Ship Yard Lights
Work Site Lighting
         

   
01/28/19 Industrial Transformer Spacing Requirements and Airflow Optimization

Article - January 29, 2019 By LarsonElectronics.com

225 KVA Power Distribution System - 480V to 208Y/120V 3PH - 18 Lift - 10 Cable - Black/Gray

Industrial Transformer Spacing Requirements and Airflow Optimization

The presence of heat has negative effects on heavy-duty machinery in industrial buildings. Heat can force units to run harder, which can result in more heat. From a long-term perspective, heat may also degrade sensitive components inside machines rapidly, resulting in premature failure.

A myriad of equipment, from motors powering conveyor belts and lighting systems to Industrial transformers, are prone to these types of challenges at work sites. Focusing on the latter, the National Electric Code (NEC) has set forth requirements surrounding proper spacing around power transformers in Article 450. The NEC guidelines are designed to promote adequate airflow and heat dissipation, while boosting operational efficiency rates.


Why Addressing Spacing? (Airflow Optimization, Building Layouts)

Proper spacing should be observed during installation of transformers to streamline cooling around the unit and the surrounding environment. Cool operating temperatures allow transformers to take on large loads without overheating or generating errors. In this case, heat is considered to be waste and must be released or ‘pushed out’ to prevent temperature rises inside transformers. Moreover, increased exposure to high temperatures can decrease the expected lifespan of transformers. This is due to degradation of insulation components inside the unit.

Spacing around transformers is an effective way to optimize airflow. Air from fans, cooling systems and blowers need space to pass or move through hot-running equipment. When machines, stations and large devices are grouped tightly together, heat will accumulate around the area due to lack of space and dissipation.

Next, in maximizing building layouts, some planners are prone to implementing aggressive floor spacing practices that group heavy-duty equipment too close together in order to save on operating or building rental costs and improve payback projections of the space. With this in mind, Article 450 can be applied to make sure spacing around transformers is fully observed.


NEC Article 450 (Scope)

The scope of NEC Article 450 includes all types of transformers, except the following (450.1): current transformers, dry-type units with components that adhere to other requirements, transformers part of X-ray or high-frequency devices, transformers used with Class 2/Class 3 circuits in compliance with Article 725, units utilized for signs and outline lights in compliance with Article 600, transformers used to electrically discharge lights in compliance with Article 410, units applied to power-limited fire alarm circuits in compliance with Article 760 (Part III) and transformers used for research or testing.

Interestingly, the coverage of the guideline extends to transformers installed in classified hazardous locations and its modifications found in Article 501-504. Less-flammable liquid-insulated, non-flammable fluid-insulated, Askarel-insulated and oil insulated transformers are also considered in Article 450.


Maximizing Ventilation and Nonlinear Loads

According to Article 450.9, power transformers with ventilation must be installed in a manner that does not block the opening. Examples of obstructions include walls, other machines and large structures. During installation, operators may refer to the nameplate of the unit, as manufacturers are required to specify clearances on transformers with ventilated openings (Article 450.11). Other specifications on the nameplate, such as temperature class and insulation, can also be used to determine spacing requirements for transformers.

A major highlight in Article 450 is nonlinear transformer loads, which can cause current distortions and interruptions. The NEC suggests that nonlinear loads are associated with increased heat. Recommendations by the NEC to mitigate unwanted heat from nonlinear loads include: derating, oversizing, boosting insulation and applying thermal protection.


Accessibility

Another reason the NEC published spacing recommendations for industrial transformers is reliable accessibility. Article 450.13 suggests that transformers and transformer vaults should be accessible by technicians, inspectors, maintenance crews and other qualified individuals. Transformers in out-of-reach or tight locations are more difficult to maintain and remove or replace.

Dry-type units rated at 1,000V (nominal or less) that are installed in open locations and on walls or structures do not have to be accessible. Additionally, low-voltage dry-type transformers should adhere to a minimum clearance of 6 inches from the wall.


Special Considerations

Article 450 provides special considerations for dry-type transformers installed in indoor locations. For units rated below 112.5 KVA, 12 inches of minimum spacing from flammable materials must be implemented. Additionally, the separation may consist of a fire-resistant/heat-insulated barrier. Dry-type transformers rated over 112.5 KVA are required to be installed in transformer rooms with fire-resistant construction. In outdoor sites, such transformers cannot be installed within 12 inches of explosive substances. Completely enclosed units with Class 155 insulation (or higher) are exempted from this practice (Article 450.22).

Lastly, for oil-insulated transformers installed in outdoor locations, adequate spacing is considered to be a safeguard against exposure to flammable materials (if present in the area). The provision that governs this practice does not specify the exact distance to implement, which must be determined based on the ‘degree of hazard involved’ (Article 450.27).





Related Categories/Products
Category/Product (click on link below for more information)
Power Distribution Accessories and Replacement Parts
Transformers/Ballasts
60kw Primary Distribution Panel - 120V/208Y - 100 Amp NEMA 3R Panel - Powder Coated Steel Frame
50 KVA Dry Type Transformer - 240/480V Primary - 1P - 120/240V Secondary - NEMA 3R
AC Disconnect Switch - Power Distribution Accessory - 60 Amp/240VAC Ratings - Overload Protection
Steel Equipment Cart - (4) 8" Casters - Powder Coated - Pintle Hitch - 24" x 36" Platform
Buck and Boost Transformer - 120/240V Primary - 16/32V Secondary
1000W Metal Halide Replacement Ballast - 480V
30 Amp Fusible Manual AC Disconnect Safety Switch - 600V AC - 3-Pole
25 HP Non-reversing Combination Starter - 600V Rated - Push Button/Selector Switch - Type 12/3R
Explosion Proof Outlet Enclosure - Class I, II, III - (2) Ports, Terminal Block - 3/4" NPT
Micro Transformer - 750 VA - 120V Input Voltage - 277V Output Voltage
Isolation Distribution Transformer; 208 Volt Primary, 480/277 Volt Secondary, 2 KVA, 3 Phase
Fast Acting Cartridge Fuse - 600V AC - 200A Rated
25 KVA Power Conditioner/Electronic Voltage Regulator - 240V 1PH Input/Output Voltage - NEMA 1
Home | Contact Us | Return Policy | Privacy Policy | Security Policy | Copyright © 2006-2018. All Rights Reserved.