Register Here | Login | My Account | Shopping Cart | Customer Service | Search| Items in Cart (0) | Quotes (0)
Call 1-800-369-6671
(Military/Intl Sales - 214-616-6180)
LIGHT TOWERS IN STOCK
       
 

Vast Inventory for Fast Shipping. Custom Builds Available, Rentals and Sales.
Most items in stock for fast shipping!! UPS Ship Map Credit cards & Paypal Accepted
Home - Articles You're NOT logged in, Please log in   

Search:
Company Information

Product #:

         
ATEX and IEC Ex Flame-proof Explosion Proof Lighting & Equipment
Explosion Proof Lights
Explosion Proof Motors - Motors for Hazardous Locations
Industrial and Vaporproof Emergency Failsafe Lighting
Industrial Cord Reels and Tool Taps
Industrial Work Area Heaters
Machine Vision Lights
Megatower™
QC Series Industrial Portable Lighting - Quick Change Mount
Rig Lights
Stadium lights
String Lights and Temporary Light Stringers
Tank Cleaning Lights
Three Phase Motor Soft Starters
Vapor Proof LED Lights
Variable Frequency Drives (VFDs)
Vehicle Mounting Plates
Workboat Light Fixtures & Lighting Equipment
Yacht Engine Room Lights
Color Changing LED RGB Lighting
Explosion Proof Cord Reels
GOLIGHT Spotlights
Larson FUTURE - Lease Lighting
Remote Area Lighting and Scene Lights
Utility Bucket Mount, Receiver Hitch & Trailer Mount Lighting
Aevum Control Lighting and Equipment - IIoT
Butane and Solvent Extraction Room Lighting and Equipment
DC to DC Transformers and Power Supplies
Explosion Proof Fans & Blowers
Explosion Proof Paint Spray Booth Approved Lights
Explosion Proof String Lights
Explosion Proof Switchgear & Controls
Fleet Service Lights and Lighting Equipment
Industrial Equipment Trailers
Industrial Handlamps & Droplights
ISO 14644/FS-209E Clean Room Lighting
LED Blasting Lights
Night Time Fishing Lights
Portable AC Power Supply Units
Portable Power Distribution Panels
Power Distribution Panels with KVA Transformers
Self-Contained Lighting
Service Pit Lighting
Solar Generators & Solar Powered Lighting
Agricultural Farm Equipment Lighting & Beacons
Explosion Proof Cameras & Surveillance Systems
Explosion Proof Emergency Lights
Explosion Proof Heaters
Garage & Gas Station Canopy Lights
LED Grow Lights
LED Lights
NDT Ultraviolet Lights
Portable Hazardous Location Lighting
Radio Communication Towers and Equipment
Salt Water Processing Equipment
Shelter & Tent Lighting
Thermal Monitoring Cameras and Systems
48V LED Equipment Lights
ATEX Rated Explosion Proof Lights
Automotive Lighting
Class Rated Signals, Alarms, and Systems
Hazardous Location Area Lights and Portable Lighting
HID Equipment Lights
Hot Work Permit Lighting and Equipment
Hunting Lights
Industrial lasers
Industrial Transformers
Light Towers
Outdoor Lighting
Remote Security and Surveillance Systems
Temporary Construction Lights
Vehicle Mounted Spotlights
Equipment & Heavy Machinery LED Light Package Fitouts
Phase Converters - Single to Three Phase
Marine Shore Power Cords and Equipment
24 Volt Military Lights
Disaster Relief / First Responders / Search & Rescue Lighting
Plastic Handcuff Key
110/120 Volt Flood Lights
Post Mount Spotlights
Magnetic Work Lights
Crank-up Light Masts
**********    
Intrinsically Safe Lights
Military Flashlights
LED Waterproof Lanterns
Work Area Lights
12 Volt Flood Lights
**********    
**********    
Boat Spotlights
New Boat Lights
HID Boat Lights
Boat Dock Lights
**********    
Remote Control Lights
Control Lights
Tow Lights
Magnetic Control Lights
**********    
NEW Lights and New Products
Evaporative Coolers
Police Equipment
AC/DC Transformers
Power Supplies
**********    
Military Spotlights 24V
Infrared Filters, Covert Covers, and Blackout IR Lenses
Military Equipment
Ultralife Batteries
Remote Control Pan Tilt Base
**********    
Larson Electronics Spotlights
Larson Electronics Parts
Replacement Lamps
Cords - Brackets
Portable Wheeled Generators
Non-Hazardous Location Extension Cords / Plugs / Outlets
**********    
HID Work Lights
HID Dive Lights
HID Off Road Lights
Acro Lights HID Lights
Halogen Lights
**********    
Acro Light Flashlight
Xenon HID Flashlights
Powerlight Flashlight
HID Flashlights
Xenon Flashlights
**********    
LED Status Lights
Forklift Lights
Tractor Lights
HID Post Mount Lights
Roof Mount Lights
Post Mount Light parts
**********    
Flashlight Holder
Magnet Spotlight Base
Tripods-Magnetic Base
**********    
Recharging Spotlights
Fire Rescue Lights
LED Street Lights
Utility Lights
**********    
Hazard Lights
Strobe Lights - Battery Operated
Strobes & Beacons
Strobe Light Bars
**********    
Headlights - Headlamps - Hard Hat Lights
Flashlights
**********    
Suction Mount Lights
Magnetic Spotlights
12/24 Volt Spotlights
Gifts For Men
**********    
**********    
New 12 / 24 Volt Lights
Explosion Proof Accessories and Replacement Parts
Explosion Proof Lighting
Explosion Proof Hand Lamps (Drop Lights)
Explosion Proof Lights - Stand/Dolly
Explosion Proof Tank Lights
Explosion Proof Phones and Intercoms
Explosion Proof Extension Cords
Black Friday & Cyber Monday Specials
Crane Lights
Explosion Proof Light Rentals
General Light Rentals
Light Tower and Light Plant Rentals
Power Distribution Rentals
**********    
Power Plant Lighting
Refinery lights
Environmental Services Lights
Aerospace Lights
Chemical Plant Lights
Food Grade Safe Lights
Film and Entertainment Lights
Handheld Meters and Devices
Waste Water Treatment Lights
Mining Lights
Ship Yard Lights
Work Site Lighting
         

   
04/19/17 Lumen Recommendations for Common and Industrial Work Spaces

Article - April 19, 2016 By LarsonElectronics.com

40 Watt 2X2 Troffer Mount LED Fixture - Replacement for Fluorescent Fixtures - 2' x 2' -3,500 Lumens

Lumen Recommendations for Common and Industrial Work Spaces

Light brightness requirements for common and industrial spaces differ greatly. To achieve consistent, bright environments, the fixture’s luminous flux (or lumen [lm], which is the SI unit of luminous flux) must be taken into consideration. By definition, the term “luminous flux” (lx) refers to the total amount of light energy emitted from a fixture in all directions.

The Illuminating Engineering Society of North America (IESNA) has published recommendations for lumen requirements in various locations. This article makes references to the IESNA Lighting Handbook for determining adequate lumen levels for various mainstream locations.


Parking Lots and Surroundings of Commercial Buildings

Parking lots have special lumen requirements, depending on the type of commercial establishment it is connected to. For example, common businesses, such as convenience stores, restaurants, malls and other retail buildings, may incorporate 60 lx minimum at horizontal illuminance and illuminance uniformity ratio of 3:1 (average to minimum) on the parking structure pavement and high traffic parts of the location. Around the area, it is ideal to maintain 30 lx at ground level. Exit and entry points of the structure and the attached building- if any, may observe a minimum of 50 lx at the pavement. If security cameras are present on the site, 12 lx vertical luminance at five feet above ground level should be implemented.

For general parking facilities, two lx of minimum horizontal illuminance (five lx for enhanced security purposes); and one lx of minimum vertical illuminance (2.5 lx for enhanced security purposes) should be observed. When dimming lights to conserve energy, the minimum value should not be lower than one horizontal lux. Enhanced security may vary, depending on the personal preferences of the lot owner, with values reaching up to 10 lux. Luminaries found in parking lots are typically cutoff or semi-cutoff variants with flat-bottomed lenses. Small parking structures may use wall mounted fixtures that are attached to an adjacent building. When using this type of light, one must be wary of unsightly glare and light pollution.


Educational, Hospitals and Hotels

Some commercial and mainstream institutions, such as schools and hospitals, may benefit from lighting level guidelines set forth by IESNA. According to the organization, classrooms in educational buildings should incorporate 300 lux, while classrooms for adult education, nurseries and lecture halls may utilize 400 lux (maintained average illuminance). Computer rooms that are menu driven may incorporate 30 lux.

For hospitals, lighting requirements also vary. General ward lighting may support 300 lux, simple examination rooms- 500 lux and examination/treatment rooms- 1,000 lux. Lighting systems in hotels and restaurants may support the following illumination levels: dining room- 100 lux, buffet- 100 lux and kitchen- 500 lux.

Inside all of the facilities mentioned above, restrooms and toilets should be illuminated with fixtures capable of 300 lux maintained average illuminance. Stairs and corridors should support 50 lux lighting levels.


Walkways

According to the IESNA Lighting Handbook, walkways located next to well-lit roadways do not require the support of separate fixtures. But to promote safety and security, most walkways still require lights to ensure timely detection of cars, bikes and other pedestrians on the path. For Type A pathways that are adjacent to commercial areas, a minimum average horizontal illuminance of 10 lx is required (22 lx vertical illuminance for special pedestrian security). For residential walkways, two lx of minimum average horizontal illuminance is sufficient (five lx vertical luminance for special pedestrian security).

Type B walkways that are isolated from general roads may support five lx for both minimum average horizontal illuminance and vertical illuminance for special pedestrian security. While pedestrian pathways inside tunnels must support at least 43 lx of average horizontal illuminance and 54 lx vertical illuminance for special pedestrian security.


Manufacturing Plants

Lumen recommendations for manufacturing plants are heavily influenced by the type of product being manufactured in the location. The following covers specific lux values for mainstream manufacturing facilities:

• Glove manufacturing: knitting and sorting (1000-2000 lux); pressing, cuffing and sewing (2,000-3,000 lux)

• Hat manufacturing: dyeing, cleaning and refining (500-750 lux); forming, finishing and ironing (1,000-1,500 lux); sewing (2,000-3,000 lux)

• Jewelry and watch manufacturing: 2,000-3000 lux

• Leather manufacturing: cleaning, cutting, stuffing and stretching (200-300 lux); finishing and scarfing (500-750 lux)

• Explosives manufacturing: 200-300 lux for all types, such as generators, stationary dryers, boiling tanks and extractors

• Paper manufacturing: beaters and grinding (200-300 lux); finishing and hand counting (500-750 lux); inspections (1,000-1,500 lux)

• Electrical equipment manufacturing: 500-750 lux for insulating and coil winding

For special tasks that require close attention to detail, such as inspections, portable luminaries may be used to support such work on the location.


Assembly Work (Industrial)

Assembly work in industrial settings are classified, based on the difficulty level of the tasks. The following lighting levels are recommended for buildings where assembly work is conducted:

• Simple: 200-300 lux

• Moderately difficult: 500-750 lux

• Difficult: 1,000-1,500 lux

• Very difficult: 2,000-3,000 lux

• Extracting: 5,000-7,500 lux

Assemblies in wood working and processing facilities also have special lighting requirements. Saw frame and bench assembly requires 300 lux at a height of 3.3 feet. Turning, cutting, sawing and dressing requires 500 lux at 3.3 feet and polishing requires 1,000 lux.


Paint Booths

Professional paint spray booths have very strict lighting needs due to the nature of work conducted inside the facility. Such requirement varies, depending on where one is in the building. For example, in paint processing rooms where dipping, simple spraying, hand painting and finishing takes place, 200-300 lux is required. For fine hand painting and finishing, lux levels could reach as high as 1,000-1,500. Extra-fine hand painting and finishing requires double the number of lux at 2,000. Rooms that are used for paint mix comparisons may utilize fixtures that are capable of producing 1,000-2,000 lux.

For general paint facilities, 200-500 lux is recommended. Automobile paint inspection works require between 3,000-10,000 lux at 3.3 feet. It is important to consider that paint booths, in addition to observing above average lux lighting levels, must adhere to special footcandle measurements.


Dock Loading and Welding

Dock loading locations are high traffic areas where equipment and products are loaded or unloaded to or from a transportation vessel, such as a truck, freight container or small vehicle. For loading and unloading on platforms, 200 lux is sufficient. Loading operations that involve freight car interiors may include fixtures capable of producing 100 lux.

Welding operations involving metals should be supported by 300 lux of maintained average illuminance. Welding orientation for workers may be conducted under 200-300 lux lighting conditions, while precision manual arc welding may be supplemented with 5,000-7,500 lux lighting levels.